Iek Contactor KMIp-22510 25A 110V/AC3 1NO (KMD21-025-110-10)

Iek Contactor KMIp-22510 25A 110V/AC3 1NO (KMD21-025-110-10)

350,80 RON
Localizare:
Traseu sugerat:  

Ofertele pentru produsul

 

Iek Contactor KMIp-22510 25A 110V/AC3 1NO (KMD21-025-110-10)

350,80 RON
Livrare gratuita
Detalii de livrare la magazin
spre magazin »
materialeelectrice.ro
Descrierea produsului
KMIp contactors with DC control coil for industrial use designed for load current from 9 up to 95 A (AC-3) are intended for actuating, shutting down and reversing of asynchronous electric motors equipped with a short-circuited rotor for the applied voltage limited to 660 V. They can be also applied for remote control of lighting (AC-5a, AC-5b), heating circuits and various low-inductance loads (AC-1), switching three-phase capacitor batteries (AC-6b) and primary windings of three-phase low-voltage transformers (AC-6a). All unit types have a single group of auxiliary NO contacts. Application area of these contactors includes controlling fan, pump, thermal curtain, furnace, overhead-track hoist, unit, lighting and automated load transfer systems; uninterruptible power systems; automation and security alarm protection devices; industrial unit management systems; switching three-phase capacitor batteries and primary windings of three-phase low-voltage transformers. Extended range of options available at the warehouse (PKI attachments, PVI time-delay attachments, RTI thermal electrical relay). 35-mm DIN-rail installation option (other manufacturers provide such option only as customized variants). Energy saving in case of applying a DC control coil. Rated control supply voltage Us at AC 50HZ: -Rated control supply voltage Us at DC: 110Rated operation current Ie , 400 V: 25Connection type auxiliary circuit: EV000415Number of auxiliary contacts as normally closed contact: 0Number of auxiliary contacts as normally open contact: 1Nominal operating AC voltage Ue: 230; 400; 660Rated insulation voltage Ui: 660Rated surge voltage: 6Conditional heat current Ith at AC-1: 40Nominal powet at AC-3 230V: 5.5Nominal powet at AC-3 400V: 11.0Nominal powet at AC-3 660V: 15.0Max short-term load: 450Conventional Short Circuit Current Inc: 3000Tightening moment: 1,2Control voltage ranges at actuation Uc: 0,85... 1,1Flexible cable without tip: 1,5... 4,0Control voltage ranges at release Uc: 0,7... 0,1Hard cable without tip: 2,5... 6,0Closing Response Time: 12... 22Response time at opening: 4... 19Mechanical wear resistance: 10.0Number of additional contacts: 1Ambient temperature: -25... +50Width: 57.0Height: 86.0Weight: 0,85Additional terminal - Nominal voltage Un AC: ≤ 660Additional terminal - Nominal voltage Un DC: ≤ 440Additional terminal - Nominal insulation voltage Ui: 660Additional terminal - Thermal resistance current In: 10Additional terminal - Minimum On Umin Capability: 24Additional terminal - Minimum On Imin Capability: 10Additional terminal - Max short-term load: 100Additional terminal - Insulation resistance: > 10Voltage type for actuating: EV000461Number of auxiliary contacts as normally closed contact, delayed switching: 0Number of auxiliary contacts as normally open contact, leading: 0Number of auxiliary contacts as change-over contact: 0Number of poles: 3Additional terminal - Section of connected conductors: 1... 4

Galerie

Păreri
Intrebari&Raspunsuri

Prețurile și informațiile de pe paginile noastre sunt furnizate de magazinele partenere și au caracter informativ, unele erori pot apărea. Imaginile produselor au caracter informativ, uneori pot include niște accesorii care nu sunt mereu incluse în pachetul de baza. Informațiile aferente produsului (imagine, descriere, preț) se pot schimba fără notificare prealabilă. Compari.ro nu își asumă responsabilitate pentru eventualele greșeli.